OleumTech Hardwired Sensors and Switches
DIFFERENTIAL PRESSURE (DP) TRANSMITTER
The Ideal Choice for Differential Pressure Monitoring Applications

HDPTxxxx
Click to expand:
1The span adjustability does not apply to the RS485 model since the reading output is digital.
2The limitation of the upper range is due to the industry rating of the sensor components.
3All models support PV reversal (high side / low side) except for the 1500 PSI model.
HIGHLIGHTS
- Pressure type: differential pressure
- Multiple measurement ranges from
-435 to 1500 PSI (-12041 to 41520 inH2O) - Reference accuracy: ± 0.075% of full span
- Stability: ± 0.2 % Upper Range Limit / 5 years
- Output signal options:
(1) 1-5 V (2) RS485 Modbus
(3) 4-20 mA (4) 4-20 mA/HART - TD ratio of up to 100:1 (accuracy not affected at
TD ratio of 10:1 and below)1 - All models support PV reversal (high side / low side)
except for the 1500 PSI model - Backlit LCD provided with both internal
and external control buttons - HART support:
- Universal and Common Practice Commands supported
- Compatible with most HART Field Communicators - Operating temperature:
-40 to 60 °C (-40 to 140 °F)
LCD: -20 to 60 °C (-4 to 140 °F) - Diaphragm option: Hastelloy C or 316L SS
- 2X overload pressure using dual diaphragm structure
- Dual seal certified per CSA C22.2 No. 30-20
- Accurate filling fluid technology eliminates effects of temperature and static pressure
- Process temp. measurement tag supported on
Modbus and HART, -40 to 85 °C (-40 to 185 °F)2 - Explosion-proof (standard on all models)
- Intrinsically Safe (4-20 mA/HART options only)
- NACE MR0175 Compliant
- Mounting Kit Available

High-Performance Differential Pressure Measurement for Industrial Applications
The OleumTech H Series Differential Pressure Transmitter is a high-performance instrument utilizing the world's most advanced monocrystalline silicon pressure sensor and patented encapsulation technology. The Differential Pressure Transmitter is designed for use in rigorous industrial applications with robust resistance to chemical exposures, mechanical loads, and EMI.
The Differential Pressure Transmitter is easy to install and operate. It can be ordered with a variety of options to fit your specific needs. The OleumTech H Series Differential Pressure Transmitter is a natural choice for a wide variety of oil, gas, water, wastewater, and other mission-critical applications that require a high level of accuracy and reliability.
Common Differential Pressure Applications:
OleumTech DP Transmitters provide accurate differential pressure measurement across a wide range of process conditions and demanding industrial applications.
Differential Pressure (DP) Flow Measurement
Differential Pressure (DP) Transmitters for Level Measurement

Differential Pressure Measurement for Heat Exchangers
Learn more about differential pressure transmitters, measurement principles, and common DP applications.
TECHNICAL SPECIFICATIONS
| HARDWARE FEATURES | |
|---|---|
| Device Functionality | ∙ Differential Pressure Transmitter |
| Output Signal Options | ∙ 1-5 V, 4-20 mA, 4-20 mA + HART, RS485 Modbus |
| Linear Output Accuracy | ∙ TD ≤ 10:1, ± 0.075% URL (With a TD ratio equal to or less than 10:1, the accuracy is 0.075% of URL) |
| ∙ 10:1 < TD ≤ 100:1, ± 0.0075% x TD URL (With a turndown ratio greater than 10:1 but equal to or less than 100:1, the accuracy is 0.0075% times the turndown of the URL) | |
| LCD Display Mode | ∙ PV (Process Variable) / mA / % / Voltage |
| Damping Time | ∙ Amplifier: 0-100 Seconds (Adj), Diaphragm Capsule and Silicone Oil Filling: ≤0.2 S, Start After Power Off: ≤ 6 S |
| Unit | ∙ PSI (Factory Default), OSI, Pa, kPa, MPa, BAR, mbar, mmHg, mHg, INHg, mmH2O, mH2O, INH2O, FTH2O, TORR, g/cm2, kg/cm2, ATM, mm, m |
| Analog Output Type | ∙ Linearity |
| Basic Operational Functions | ∙ Set PV = 0, Zero Adj (4 mA Re-range with Pressure), Span Adj (20 mA Re-range with Pressure), Factory Reset |
| ELECTRICAL SPECIFICATIONS | |
| Power Supply | ∙ 1-5 V: 9-55 Vdc Max |
| ∙ 4-20 mA: 16.5 Vdc to 55 Vdc Max (28 Vdc Max for IS) | |
| ∙ 4-20 mA/HART: 16.5 Vdc to 55 Vdc Max (28 Vdc Max for IS) | |
| ∙ RS485 Modbus: 9 to 30 Vdc Max | |
| Power Consumption | ∙ 1-5 V: 4 mA (Max) / 4-20 mA/HART: 21 mA (Max) / HART Multi-drop: 4 mA / RS485: 12 mA (Max) |
| Surge Protection | ∙ The transmitter has been tested to withstand a transient surge up to 2000 V (common mode) or 1000 V (normal mode) without damage (Per IEC Std. 61000-4-5) |
| MECHANICAL SPECIFICATIONS | |
| Dimensions (LCD) | ∙ 5.2" (W) x 7.9" (H) x 5.2" (D) / 131 mm (W) x 200 mm (H) x 133 mm (D) |
| Weight | ∙ Net: 8.5 lbs. (3.9 kg) / Gross: 9.5 lbs. (4.3 kg) |
| Package Dimensions | ∙ 9.5" (W) x 8" (H) x 8.25" (D) / 241 mm (W) x 203 mm (H) x 210 mm (D) |
| Enclosure Casing Material | ∙ Type 4X Aluminum; IP66 |
| Cable Entry Ports | ∙ (2) 1/2" NPT, 1 Plug Included |
| Flange Options | ∙ H1 (Drain Valve on Rear End of Flange), H2 (Drain Valve on Upper End of Flange), H3 (Drain Valve on Down End of Flange) |
| CERTIFICATION & COMPLIANCE | |
|---|---|
| Safety | ∙ IS Option Available on 4-20 mA and 4-20 mA/HART Only, Explosion-proof (Standard) All Models |
| cCSAus | ∙ Class I, Division 1, Groups A, B, C, D T6; Class I, Division 2, Groups A, B, C, D T4 |
| ∙ Class II, III Division 1, Groups E, F, G T80 °C | |
| ∙ Ambient Temperature: Ta = -40 to 60 °C (-40 to 140 °F) | |
| ∙ Differential Pressure Transmitters, approved for hazardous locations, are dual seal certified per CSA C22.2 No. 30-20. | |
| NACE | ∙ NACE MR0175 Compliant |
| GENERAL SPECIFICATIONS | |
|---|---|
| Operating Temperature | ∙ -40 to 60 °C (-40 to 140 °F) / LCD -20 to 60 °C (-4 to 140 °F) |
| Storage Temperature | ∙ -40 to 110 °C (-40 to 230 °F), Integrated LCD: -20 to 70 °C (-4 to 158 °F) |
| Process Temperature | ∙ Silicone Oil Filling (S): -40 to 120 °C (-40 to 248 °F) |
| Process Temp. Measurement | ∙ -40 to 85 °C (-40 to 185 °F), ± 4 % Accuracy (°C), Supported on Modbus and HART (SV) Models |
| Operating Humidity | ∙ 5 to 100% @ 40 °C (104 °F) |
| Warranty | ∙ 2-Year Parts and Labor |
Frequently Asked Questions
Explore these frequently asked questions to learn more about OleumTech Differential Pressure Transmitters.
What is a differential pressure transmitter?
A differential pressure transmitter, also known as a DP transmitter, is an instrument that measures the pressure difference between two points. By comparing the high-pressure and low-pressure sides of the sensor, it provides an accurate differential pressure measurement for applications including flow measurement, level measurement, filter monitoring, and process control.
How does a DP transmitter work?
A differential pressure (DP) transmitter measures the difference between two points using separate high-pressure (HP) and low-pressure (LP) ports. Pressure is applied to an internal sensing diaphragm, which deflects in proportion to the differential pressure. The transmitter converts the applied pressure readings into a standardized output signal (such as PSI) for industrial control systems, allowing operators to accurately monitor flow, liquid level, filter condition, and other critical process variables in real time.
What is differential pressure?
Differential pressure is the difference in pressure between two separate points within a process. Measuring differential pressure provides valuable information about process conditions and is commonly used to calculate flow, determine liquid level in pressurized vessels, monitor filter performance, and identify pressure losses across piping and process equipment.
What accuracy can OleumTech Differential Pressure Transmitters achieve?
OleumTech DP Transmitters provide high-performance measurement accuracy for demanding industrial environments. The meters offer:
• Reference accuracy: ± 0.075% of full span
• Stability: ± 0.2 % Upper Range Limit / 5 years
• TD ratio of up to 100:1
What industries use DP transmitters?
Differential pressure transmitters are used across many industries that require accurate process measurement and control, including:
- Oil & Gas
- Chemical Processing
- Petrochemical
- Water & Wastewater
- Power Generation
- Industrial Manufacturing
Can a DP transmitter measure flow?
Yes. Differential pressure transmitters are widely used for flow measurement when paired with primary flow elements such as orifice plates or venturi tubes. The transmitter measures the pressure drop across the primary element, allowing the flow rate of liquids, gases, or steam to be calculated.
Can differential pressure transmitters measure level?
Yes. OleumTech DP Transmitters are commonly used for continuous level measurement in pressurized tanks and vessels. By measuring the hydrostatic pressure difference between two points, the transmitter can accurately determine liquid level white providing reliable performance in demanding industrial environments.
What are the advantages of OleumTech Differential Pressure Transmitters?
Key benefits of OleumTech DP Transmitters include:
- High reference accuracy (±0.075% of full span)
- Rugged construction for harsh industrial environments
- Multiple communication and output options
- Hazardous location approvals
- Excellent long-term stability and repeatability
- Easy integration with PLC, RTU, DCS, and SCADA systems
Are OleumTech DP Transmitters suited for hazardous locations?
Yes. OleumTech Differential Pressure Transmitters are designed for hazardous industrial environments. The 4–20 mA/HART model is Intrinsically Safe, while all models are Explosion-proof, making them suitable for demanding oil & gas and industrial applications.
What communication protocols are supported?
OleumTech DP Transmitters offer multiple signal output options to simplify integration with existing automation systems, including:
- 1-5 V
- RS485 Modbus
- 4-20 mA
- 4-20 mA/HART
Follow Us