OleumTech Hardwired Sensors and Switches
GUIDED WAVE RADAR LEVEL TRANSMITTER
Guided Wave Radar (GWR) For Continuous Level & Interface Measurement

HGWRxxxx
Ordering Information

HIGHLIGHTS
- Harness the power of advanced Guided Wave Radar technology
for precise product and interface level measurement with
no moving parts, ensuring unmatched reliability and performance - Delivers proven accuracy in harsh conditions with presence of
vapor, foam, corrosive liquids, and condensation - All flexible probes are detachable and can be cut for a perfect fit
Up to 787 inches / 66 ft
Choose 316L SS or PFA-coated cable option - PFA-coated cable provides resistance against paraffin, build-up, and corrosion, extending lifespan and maintenance cycle
- Accuracy: ±2 mm (0.079″)
- Choose from two output configuration options:
RS485 Modbus with (1) 4-20mA output (default)
or 4-20mA/HART option - Multiple liquid compatibilities
- Transmitter is fully configurable via its user-friendly LCD display
interface or dedicated OleumTech GWR Software - Bright, backlit, always-on LCD for clear visibility in any lighting
- Designed for ease of installation and servicing
- Supports -14.5 to 580 psi operating pressure range
- Supports a wide process temperature range
-40 ˚C to 150 ˚C (-40 ˚F to 302 ˚F) - Zone 0/1, Explosion-proof
Reduce Maintenance and Improve Reliability with Guided Wave Radar
The OleumTech Guided Wave Radar Level Transmitter is designed for liquids in storage tanks, pressure vessels, and process applications. GWR level measurement is ideal for upstream production tanks and separators, midstream collection tanks, chemical tanks, and more!
With no moving parts, guided wave radar provides reliable, low-maintenance level measurement in demanding process conditions. The OleumTech GWR Level Transmitter delivers accurate continuous level and interface measurement, even in applications with vapor, foam, condensation, corrosive liquids, paraffin, or buildup.
| HARDWARE FEATURES | |
|---|---|
| Device Functionality | ∙ H Series Guided Wave Radar Level Sensor Transmitter |
| ∙ Provides Product and Interface Level Measurements (For Liquid in Storage Tanks) | |
| Configuration | ∙ via OleumTech GWR Software or LCD Module |
| Probe Type and Material | ∙ Flexible, Detachable (Threaded), Field-Cut Design: 316L SS or PFA Coated 316L SS |
| Accuracy | ∙ ±2 mm (0.079") |
| Medium Supported | ∙ Medium with Dielectric Constant Greater than or Equal to 1.8 |
| Min/Max Measuring Range | ∙ Minimum Cable Length 39.37” / 3.3 ft / 1 m | Maximum Cable Length: 787” / 66 ft / 20 m |
| Measurement Interval | ∙ ~1 Second |
| Interface | ∙ RS485 Modbus (Default Slave ID 1), 4-20 mA/HART (Default Slave ID 0) |
| Baud Rate | ∙ 1200-38,400 bps (9600 Default) |
| FailSafe Mode | ∙ Damaged LCD will not affect normal operation of level indication. |
| ∙ All data will be stored in memory even when power is off. | |
| MECHANICAL SPECIFICATIONS | |
| Dimensions | ∙ 5" (W) x 7.6" (H) x 4.4" (D) / 127 mm (W) x 193 mm (H) x 112 mm (D) |
| Package Dimensions | ∙ 10.25" (W) x 14" (H) x 6.5" (D) / 260 mm (W) x 356 mm (H) x 165 mm (D) |
| Package Weight | ∙ ~4.5 lbs/ 2.0 kg (Head Only) |
| Electrical Connection | ∙ Two(2) 1/2" NPT Female Ports |
| Process Connection | ∙ 1" NPT Male |
| Enclosure Seals | ∙ Fluoroelastomer (FKM) |
| Materials (Wetted Parts) | ∙ 316L SS Probe: 0.16" / 4 mm Diameter |
| ∙ PFA Coated 316L SS Probe: 0.25" / 6.4 mm Diameter | |
| ∙ 316L SS Sink Weight: 6.5" x 1.14" / 165 mm x 29 mm | 1.7 lbs / 771.1 g | |
| Enclosure Casing Material | ∙ Type 4X Aluminum; IP67 |
| ELECTRICAL SPECIFICATIONS | |
| DC Power Input | ∙ RS485 + 4-20mA Model: 20-28 Vdc, RS485 Output Only: 9-28 Vdc | 4-20mA/HART Model: 16-28 Vdc |
| Current Consumption | ∙ RS485 + 4-20mA Model: 0.72W Max | 4-20mA/HART Model: 0.53W Max |
| CERTIFICATION & COMPLIANCE | |
|---|---|
| Safety | ∙ Explosion-proof for Use in Hazardous Environments |
| ∙ IECEx Ex db IIC T6 Ga/Gb Zone 0/1 | |
| ∙ Conforms to the Requirements of: IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60079-26 |
| GENERAL SPECIFICATIONS | |
|---|---|
| Operating Pressure | ∙ Process Pressure Range: -14.5 to 580 psi (-0.1 to 4 Mpa) |
| Operating Conditions | ∙ Sensor: Process Temperature (Zone 0/1): -40 °C to 150 °C (-40 °F to 302 °F) |
| ∙ Transmitter: Ambient Temperature (Zone 0/1): -40 °C to 70 °C (-40 °F to 158 °F) | |
| ∙ Transmitter: Ambient Temperature (Non-Hazardous Applications): -40 °C to 80 °C (-40 °F to 176 °F) | |
| ∙ Vibration Resistance: 10 m/s² (10-150 Hz) | |
| ∙ Humidity: 0 to 95 % HR, Non-Condensing | |
| Warranty | ∙ 2-Year Parts and Labor |
| Country of Origin | ∙ USA |
Follow Us