WIRELESS HYDROSTATIC LEVEL TRANSMITTER
Battery-Powered Self-Contained Level Monitoring Solution

WT-LL5
HIGHLIGHTS
- 1-5 Vdc hydrostatic sensor input, 24-bit ADC
- 1 discrete input
- Up to a 10-year battery life
- Advanced local LCD display interface
- Supports Over-the-Air (OTA) functionality for updating the device configuration/calibration (900 MHz only)
- Self-contained, rugged design
- Installs in minutes
- IP66, -40 °C to 70 °C (-40 °F to 158 °F)
- 900/915 MHz range: Up to 1.4 Miles / 2.3 km with Clear Line of Sight
- 2.4 GHz range: Up to 1.9 Miles / 3.1 km with Clear Line of Sight
- 868 MHz range: Up to 1.5 Miles / 2.4 km with Clear Line of Sight
- Secure AES encryption
- Class I, Division 1 (Zone 0), Intrinsically Safe

Supports 1-5 V Hydrostatic Level Sensors
The OleumTech® OTC Wireless Hydrostatic Level Transmitter is designed to accurately measure liquid levels by monitoring the pressure at the bottom of vented top-mount tanks, deep wells, water towers, rivers, and lakes. The WT-LL5 Level Transmitter features a 0-5 Vdc analog input and delivers high-resolution, 24-bit analog-to-digital conversion (ADC) for precise readings. It can supply up to 12 Vdc to connected sensors and offers flexibility by allowing users to choose their preferred sensor and mounting method. Additionally, the WT-LL5 includes a discrete input for added versatility. Powered by a replaceable battery pack, this ultra-low-power transmitter ensures long-lasting performance with a lifespan of up to 10 years. A convenient push-button LCD interface enables easy device configuration and provides immediate access to real-time process data.
Reliable, Scalable and Safe
The field-proven wireless transmitter seamlessly communicates with an assigned wireless gateway within the OTC Wireless Sensor and I/O Network, forming a highly scalable system that can accommodate virtually any I/O requirement.
The OleumTech Wireless Transmitter is certified for use in Class I, Division 1 (Zone 0) hazardous locations. It is intrinsically safe, designed not to cause a spark, and can be serviced without being removed from a process.
This product is also available without a local display.
- 0-5 PSI – 1-5 V, 25 ft Cable Length, Weight Kit Included, Part# A005025K
- 0-10 PSI – 1-5 V, 50 ft Cable Length, Weight Kit Included, Part# A010050K
- 0-25 PSI – 1-5 V, 75 ft Cable Length, Weight Kit Included, Part# A025075K

TECHNICAL SPECIFICATIONS
| WIRELESS COMMUNICATIONS | |
|---|---|
| Radio Band | ∙ ISM Band (License-Free) |
| 900 MHz / 915 MHz | ∙ FHSS, FSK, AES Encryption 256-bit (900 MHz), 128-bit (915 MHz) |
| 2.4 GHz | ∙ DSSS, AES Encryption 128-bit |
| 868 MHz | ∙ LBT-AFA, AES Encryption 128-bit |
| Bit Rate | ∙ 900/915 MHz: 9600 bps / 115.2 kbps; 2.4 GHz: 250 kbps; 868 MHz: 80 kpbs |
| Output Power (Max) | ∙ 900/915 MHz: 10 mW; 2.4 GHz: 63 mW; 868 MHz: 25mW |
| Receiving Sensitivity | ∙ 900/915 MHz: -110 dBm @ 9600 bps, -100 dBm @ 115.2 kbps |
| ∙ 2.4 GHz: -101 dBm @ 250 kbps; 868 MHz: -106 dBm @ 80 kbps | |
| RF Range | ∙ 900/915 MHz: Up to 7500 Feet / 1.4 Miles / 2.3 km with Clear Line of Sight |
| ∙ 2.4 GHz: Up to 1.9 Miles / 3.1 km with Clear Line of Sight | |
| ∙ 868 MHz: Up to 1.5 Miles / 2.4 km with Clear Line of Sight | |
| HARDWARE FEATURES | |
|---|---|
| Device Functionality | ∙ Liquid Level Sensing Wireless Transmitter Using Hydrostatic Technology |
| Embedded Controller | ∙ Ultra-Low Power RISC Microcontroller with Internal FLASH (Field Upgradeable) |
| Configuration | ∙ Standard RS232 Serial / BreeZ® Software for PC |
| Sensor Type | ∙ Submersible Hydrostatic Pressure Sensor (Sold Separately), Wide Operating Temperature Range |
| Inputs | ∙ 1 Analog Input: 0-5 Volt, 24-bit ADC ∙ 1 Discrete Input: Dry Contact, NPN (Sink), Debounce Filter 20 - 2000 ms, 16-bit Counter (Available on WT-LL5) |
| Power Source | ∙ Self-Contained, Internal 3.6 Vdc Lithium Battery |
| Available Power | ∙ Supplies Sensor Power Up to 12 Vdc |
| Sensor Power Up Delay | ∙ Approximately 500 ms |
| Internal Battery Life | ∙ Up to 10 Years, Based on User Defined Reporting Intervals |
| Local LCD Display | ∙ 32-Character Display (16x2 Lines) with 4 Function Keys + Read Button |
| Instant Displayable Read | ∙ Level / Discrete Input / Battery Voltage / RF Status |
| Local Configuration | ∙ Integral LCD with Push Button Interface |
| Device Diagnostics | ∙ Health Tags: Battery Voltage, Received Signal Strength Indication (RSSI), RF Refresh, RF Timeout |
| MECHANICAL SPECIFICATIONS | |
| Dimensions | ∙ 5.5" (W) x 12.8" (H) x 4.4" (D) / 140mm (W) x 325mm (H) x 112mm (D) |
| Dimensions, Sink Weight | ∙ 3.36" / 85.3mm (Height) x 1.25" / 31.8mm (Outer Diameter), 0.5" / 12.7mm (Inner Diameter) |
| Package Dimensions | ∙ 10.25" (W) x 14" (H) x 6.5" (D) / 260mm (W) x 356mm (H) x 165mm (D) |
| Package Weight | ∙ ~7 lbs / 3.2 kg |
| Connection Fitting | ∙ WT-LL4: 1.5" NPT Male Compression Fitting; WT-LL5: 3/4" NPT Female |
| Enclosure Casing Material | ∙ Type 4X Aluminum; IP66 |
| GENERAL SPECIFICATIONS | |
| Operating Conditions | ∙ Ambient Temperature (Class I, Division 1 / Zone 0): -40 °C to 70 °C (-40 °F to 158 °F) |
| ∙ LCD Screen -20 °C to 70 °C (-4 °F to 158 °F) | |
| ∙ Ambient Temperature (Non-Hazardous Applications): -40 °C to 80 °C (-40 °F to 176 °F) | |
| ∙ LCD Screen -20 °C to 70 °C (-4 °F to 158 °F) | |
| ∙ Humidity: 0 to 99 %, Non-Condensing | |
| Warranty | ∙ 2-Year Parts and Labor |
| Country of Origin | ∙ USA |
| CERTIFICATIONS & COMPLIANCE | |
|---|---|
| EMC/EMI | ∙ FCC Part 15 (USA), IC ICES-003 (Canada), ACMA (Australia) |
| ∙ AS/NZS CISPR 32 (Australia), EN55032 & EN55024 (EU) | |
| Safety | ∙ Class I, Division 1, Groups A, B, C, D T3C; Ex ia IIC T3 |
| ∙ Class I, Zone 0; AEx ia IIC T3 | |
| ∙ ATEX: Sira 13ATEX2142X; Ex ia IIC T3 Ga; II 1 G | |
| ∙ IECEx: SIR 13.0054X; Ex ia IIC T3 Ga | |
| GENERAL SPECIFICATIONS | |
|---|---|
| Operating Conditions | ∙ Ambient Temperature (Class I, Division 1 / Zone 0): -40 °C to 70 °C (-40 °F to 158 °F) |
| ∙ LCD Screen -20 °C to 70 °C (-4 °F to 158 °F) | |
| ∙ Ambient Temperature (Non-Hazardous Applications): -40 °C to 80 °C (-40 °F to 176 °F) | |
| ∙ LCD Screen -20 °C to 70 °C (-4 °F to 158 °F) | |
| ∙ Humidity: 0 to 99 %, Non-Condensing | |
| Warranty | ∙ 2-Year Parts and Labor |
| Country of Origin | ∙ USA |
| ORDERING INFORMATION | |
|---|---|
| Model Numbers | ∙ WT-0900-LL5, WT-0915-LL5, WT-2400-LL5, WT-0868-LL5 |
| Wirelessly Connects To | ∙ OTC Wireless Gateway |
| Configuration Cable | ∙ SX1000-CC2, OTC Configuration Cable Kit |
| Replacement Battery | ∙ Use OleumTech SX1000-BP3 Only |
Follow Us