HW-H2S
HIGHLIGHTS
- H2S measurement range: 0.0 to 100.0 ppm (200.0 ppm optional)
- Resolution: 0.1 ppm
- Field replaceable sensor module
- RS485 Modbus Interface
- 2 configurable alarm setpoints: high and high-high
- 2 alarm status DOs (Solid State Relay)
- Field calibratable, 2 points (zero and custom: 10-50 ppm)
- Dust/splash guard included
- Bump tests and alarm acknowledgments can be
performed using just the external scroll button - Provides helpful sensor maintenance tags such as
total days since last bump test and calibration - Advanced local LCD display interface
- 9-30 Vdc
- IP66, -40 to 50 °C (-40 to 122 °F)
- Class I, Division 1 (Zone 0), Intrinsically Safe
- Wireless version available

Integrated H2S Detection Solution
The OleumTech® H Series Hydrogen Sulfide (H2S) Gas Detection Transmitter is an RS485 Modbus interface solution for continuously monitoring air quality and generatong alarms when H2S concentration levels exceed user-configured setpoints to ensure a safe working
environment. The transmitter is equipped with a replaceable H2S sensor module enclosed in a robust 316 stainless steel housing with a steel mesh filter. A dust/splash guard is also included for added layer of protection. The H2S Transmitter provides helpful sensor maintenance tags like bump test count, total days since last successful bump test, and calibration. In addition, the HW5000-H2S Transmitter provides two solid state relay outputs for alarm annunciation.
Reliable, Scalable and Safe
The local user interface allows for device configuration and instant data access. Bump tests and alarm acknowledgments can be performed using a single external button.
The OleumTech H Series H2S Transmitter, HW5000-H2S, is Intrinsically Safe and is certified for use in Class I, Division 1 hazardous locations. The instrument can be ordered with 12 or 24 V IS Barrier Boards. The OleumTech HW5000-H2S is a natural choice for a wide variety of oil, gas, water, wastewater, and other mission-critical applications that require a high level of accuracy and reliability.
HARDWARE FEATURES | |
---|---|
Device Functionality | ∙ RS485 Modbus Transmitter with Hydrogen Sulfide (H2S) Gas Detection Capabilities |
Embedded Controller | ∙ Ultra-Low Power RISC Microcontroller with Internal FLASH (Field Upgradeable) |
Configuration | ∙ USB to RS485 Converter (SX1000-CC8) |
Interface | ∙ RS485 Modbus |
Baud Rate | ∙ 1200-57,600 bps |
Local Configuration/Calibration | ∙ Integral LCD with Four Function Key Interface |
Bump Test | ∙ Bump Test / Alarm Acknowledgment Performed Using the External Scroll Button |
MECHANICAL SPECIFICATIONS | |
Dimensions | ∙ H2S: 5.5" (W) x 10.2" (H) x 4.5" (D) / 138 mm (W) x 259 mm (H) x 115 mm (D) / H2S-A: 15" / 379 mm (H) |
Package Dimensions | ∙ 10.25" (W) x 14" (H) x 6.5" (D) / 260 mm (W) x 356 mm (H) x 165 mm (D) |
Package Weight | ∙ 4.5 lbs/ 2.1 kg |
Connection Fitting | ∙ 3/4" NPT Female |
Enclosure Casing Material | ∙ Type 4X Aluminum; IP66 |
ELECTRICAL SPECIFICATIONS | |
DC Power Input | ∙ 9-30 Vdc (30 V Max) |
Current Consumption | ∙ 25 mA Peak / 1.2 mA Idle |
IS Safety Protection | ∙ Barrier Board (See Part Numbers under Ordering Information) |
CERTIFICATION & COMPLIANCE | |
---|---|
Safety | ∙ Intrinsically Safe for Use in Hazardous Environments |
∙ Class I Division 1, Class l, Group A, B, C, D, Zone 0, Ex ia llC T4, AEx ia llC T4 Ga | |
∙ ATEX: Sira 16ATEX2229X; Ex ia IIC T4 Ga | |
∙ IECEx: SIR 16.0079X; Ex ia IIC T4 Ga |
GENERAL SPECIFICATIONS | |
---|---|
Operating Conditions | ∙ Sensor -40 to 50 °C (-40 °F to 122 °F) |
∙ Transmitter: Ambient Temperature (Class I, Division 1): -40 °C to 50 °C (-40 °F to 122 °F) | |
∙ LCD Screen -20 °C to 70 °C (-4 °F to 158 °F) | |
Warranty | ∙ 2-Year Parts and Labor |
Country of Origin | ∙ USA |
HYDROGEN SULFIDE (H2S) DETECTION SENSOR | |
---|---|
H2S Measurement Range | ∙ 0 to 100 ppm (Maximum Overload: 200 ppm) |
Resolution | ∙ 0.1 ppm |
Response Time (T90) | ∙ ≤ 45 Seconds |
Temperature Range | ∙ -40 °C to 50 °C / -40 °F to 122 °F |
Storage Temperature | ∙ 10 °C to 30 °C / 50 °F to 86 °F (Recommended) |
Pressure Range | ∙ 1 ± 0.1 atm |
Humidity | ∙ 15 to 90 % RH Non-Condensing |
Expected Operating Life | ∙ 2 Years |
Field Calibratable | ∙ 2-Point Calibration: Zero and Custom Level Between 10-50 ppm in 5 ppm Increments (Within +/- 5 ppm of Reading) |
Sensor Module | ∙ Replaceable Type, Field Swappable |
ORDERING INFORMATION | |
---|---|
Model Numbers | ∙ HW5000-H2S |
IS Barrier Boards | ∙ 12 V Kit: SX1000-B12, RS485 Module (61-6002-001) + 12 V Module (61-6003-001) |
∙ 24 V Kit: SX1000-B24, RS485 Module (61-6002-001) + 24 V Module (61-6004-001) | |
Configuration Kit | ∙ H Series Configuration Kit (SX1000-CC8) |
Bump Test Kit | ∙ SX1000-BTK (Includes Housing Adapter, 3/16” (ID) Barb, Removable Plug, and 18” Tubing) |